emc vnx wartung. The unit supports 100 GB, 200 GB and 800 GB SSDs; 300 GB and 600 GB. emc vnx wartung

 
 The unit supports 100 GB, 200 GB and 800 GB SSDs; 300 GB and 600 GBemc vnx wartung  Web Recently I Bought An Emc Vnx 5200

3. The vVNX vVols Technical Preview represents the initial phase of showing the public how we plan to integrate in this new framework, with heavy focus on ease-of-use for users to quickly. I was also provided with a separately boxed set of six 1TB 7,200-rpm NL-SAS. First, you need a switch. 14-95. Included in this. EMC VNX 7. P/N 300-013-315. Let’s talk a little about VNX for File and monitoring features provided by Unisphere. Edit the snmpd file. The SP or DAE containing the faulted part will be marked with a health icon, or the top level component (SP or DAE) will already be expanded. As per emc171987, there is no new MIB for the VNX Series. You’ll have the power to handle the most rigorous workloads. EMC® VNX® VNX5200™ Block Installation Guide P/N 300-999-786 REV 02 fTasks to Complete after a VNX Installation Two Sections have been added to the VNX w/ MCx installation. Select the Reports tab, then Report Templates. Check Version: 7. First thing’s first, connect a switch to the two network ports on the VNXe. If you want to check the performance levels of a VNX array, you can use one (or a combination) of these methods Unisphere Analyzer. 021. Unisphere supplies storage administrators with intuitive task. 5 OS & 7. Follow the wizard to set up the ESRS and test the ConnectHome process. Rev 01. Manufacturer part SR42UB1032. Click on ok. 2013 EMC Proven Professional Knowledge Sharing 6 Looking for Descriptions, Features (old and new), and Further Improvements in VNX Storage Between Flare versions, sometimes new things are added or improvements are done to actual 13-07-2018 05:00 AM. Cisco UCS Director EMC VNX Management Guide, Release 5. 0266-1. See the table below for the list of alerts available in the Management Pack. To kick off your health check, simply login to the control station using an SSH client and run the command “ nas_checkup ”. We opened a case to EMC, and received a new CS that we should have used to replace the faulty CS . watch4net. The EMC® VNX® Series Version 5. 1 EMC® Secure Remote Support for VNX™ P/N 300-013-445 Rev 02 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 Enable write cache: System --> Under System Management click on System Properties --> Go to SP Cache --> check write cache (enable) Note: It is recommended that the default setting of write cache: Enabled remain in place. 2gb of drives and 4 port fc module. The new release includes changes to VNX's software to take full advantage of SSD speeds; previous generations simply swapped spinning disk with SSDs, which. 6GHz, quad-core Xeon 5600 processor with 8GB of RAM and a maximum of 125 drives with the following host connectivity option: FC, iSCSI, and FCoE. CLI Path to naviseccli. The VNX5500 is a mid-range/mid tier storage platform. 24 hours a day, 7 days a week. 7. 8 TB, the VNX-F5000 provides a new lower price. The EMC driver framework with the VNX plug-in is referred to as the VNX driver in this document. This introductory model for the VNX unified platform is designed for the mid-range entry space. 119 EMC Unisphere 1. its a EMC VNX 5400(Unified) storage . The result is that VNX OE software believes the Storage Processor is hung, resulting in the (deliberate]) WatchDog panic. Password: emc. 0 enhancements that include: • Continuous Availability (CA) – Continuous Availability enables applications to be vVNX Community Edition is a freely downloadable virtual storage appliance (VSA), that can be downloaded onto ESX 5 or 6 servers, to run a software-defined unified VNX array. Media & master servers are Installed with rhel6. Enter the Service password and click OK to log in to the Service System page. Release Notes P/N 302-000-403 REV 20 August, 2015. To quote EMC “The code has been written so that the rebuild process is considered a lower priority than the Host IO. Block Storage. Dell EMC VNX driver. are supported with VNX D@RE. If the radio button is set to Automatic,. There are other hybrid solutions on the market that use flash more effectively than EMC’s reactive tiering. ARCHITECTURE Based on the powerful new family of Intel Xeon-5600 processors, the EMC VNX implements a modular architecture that integrates hardware components for block, file, and object with concurrent support for native NAS, iSCSI, Fibre Channel, and FCoE protocols. June 27, 2012. )) 2x 10 core CPUs per blade, and 128GB per blade. Oracle Java SE (April and July 2018 CPU)Manage your Dell EMC sites, products, and product-level contacts using Company Administration. The tool is available on the store page. Additional recommendations. Responsable for the Storage products,. This guide describes one of five models available in the VNX series, the VNX5300. I've tried so many different workarounds with no results ex. 1. This direction was first. On a separate host, install latest. 1 Overview EMC VNX5300 Hardware Information Guide 5 DAE6S) or a 25 drive 2. this is the array configuration file. 8. Spec SheetVNXe cli cmds. Note: Only VNX Block File produces actual alerts. EMC VNX File Overview provides at-a-glance heatmaps depicting the overall health of your VNX File resources (file arrays, virtual data movers, NFS exports, file systems, etc. Experience in day to day Operations and Troubleshooting support in Commvault 9, 10 & 11. EMC VNX driver interacts with configured VNX array. Page 1 (NAS) functionality via two to eight Data Movers and Block (iSCSI, FCoE, and FC) storage via dual storage processors using a full 6-Gb/s SAS disk drive topology. But before we ship it back to EMC we need to employ a. Page 33 The optional DAEs use a 2U rail kit for the 25 2. By default, this privilege is granted to all local administrators, so add the cava account to the local administrators folder. Logging in SPB. Once claimed by the filter, a vendor-specific VAAI plugin will claim and then manage your device. Note Do not request a specific support representative unless one has already been assigned to your particular system problem. 1 cm); Depth – 39. 8 TB – rack-mountable – Serial Attached SCSI 2 – HD 600 GB x 8 – RAID 0 – 1 – 3 – 5 – 6 – 10. Unisphere provides a flexible, integrated experience for managing Unity and Unity XT storage systems as well as previous generation Dell unified storage-the VNX and VNXe series. 5", 25-bay 2. Reducing operating costs – According to our calculations, our Dell EMC VNX 5200 storage maintenance saves our customers around 40% compared to the same service provided by. Requirements Import the. This forces the ESXi host to sync with the changes on the underlying expanded devices. Start a Conversation. I have to say NetApp has a little bit advantage on performance monitoring against VNX - they provide "free" performance monitoring ("stat" or via SNMP). The security of our products is a top priority and critical to protecting our customers. EMC VNX driver interacts with configured VNX array. Multicore optimization with MCx boosts transaction performance by a factor of 4x and takes full advantage of flash data storage. 5" SAS / Flash. Set the access-checking policy on page 36 describes this task. down vote favor. Recovery came in 2003 with $6. This article describes the new generation VNX platform system control station which includes hardware information and cable information. The component has scalability and redundancy. I explain shortly how to provision LUNS, how to create storage. Cisco UCS Director Management Guide for Cisco UCS Manager, Release 6. This guide describes one of five models available in the VNX Series, the EMC. or its subsidiaries. This guide describes one of five models available in the VNX Series, the EMC. This paper provides a detailed description of this technology and describes how it’s implemented on VNX2 series storage systems. The unit's two-rack-unit-sized enclosures fit up to 25 2. The Manage Solution window will appear as follows: Note: Click the Add icon above the Instance Name (not shown here) to create multiple adapter instances. Prior to configuring the Management Pack for Dell EMC VNX Block in VMware Aria Operations, ensure the following pre-configuration tasks are completed for your VNX Block File or Block storage system: n. March 2016 . The Control Station runs an EMC modified version of Red Hat Linux. We need constinous performance monitoring, normally most of people keep the detailed performance data in 1~2 months. The second part of the drives, if the drive is large enough in capacity, can be used to create a User raid group and User LUNs. EMC Sustaining Engineering has a recovery procedure for this "stuck equalize" issue that refers to various revisions of FLARE none of which are current. 1. 0 solution features EMC VMX series storage controllers. 6. This guide describes one of five models available in the VNX Series, the EMC. VNX Snapshots White Paper 5 6. 0 Configuring and Managing CIFS on VNX™ P/N 300-011-826 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000VNX 5100, 5200, 5300, 5400, 5500, 5600, 5700, 5800, 7500, 7600, 8000, F5000, F7000. New to EMC system. Don’t get m e wrong, FAST VP and FAST Cache are both great, and they both helped our environment to improve performance capabilities for VNX customers. When viewing metrics in the real-time dashboards, new data points are automatically added every 5 seconds. (56 pages)Note: The EMC white paper VNX Configuration Recommendations for SAP HANA TDI, page 20, does not mention these changes because the white paper had been created before the kernel bug was detected. Click System > System Health. The VNX5500 model can hold 250 drives, scalability of up to 480TB and with system memory of up to 12GB at the block level along with the support of FC, iSCSI and FCoE connectivity. bind. conf for. Part Number h11181. configure and deploy DELL EMC VNX Series Block (FC, iSCSI and FCOE) and File (NFS, pNFS and CIFS) based storage solutions in heterogeneous virtualized open systems environments. NVMe is a set of standards which define a PCI Express (PCIe) interface used to efficiently access data storage volumes based on Non-Volatile Memory (NVM) media, which includesEMC VNXe3200 midrange NAS system technical overview. Unisphere Analyzer ENABLER. 3. Multicore optimization with MCx boosts transaction performance by a factor of 4x and takes full advantage of flash data storage. VNX lets customers use traditional spinning disk and SSD-based flash storage in the same array. For more details about the VNX series, refer to the Introduction to EMC VNX Series Storage Systems white paper available on EMC Powerlink®. 5" & 2. By: Dave Raffo. xml. number label locations of orderable parts for the EMC VNX5500 platform. 3. A SLES 12SP4 client is mounting a cifs share from Dell/EMC VNX 5400 storage. June 26, 2012. VNX series systems are available in the following configurations: VNX Block, VNX File, VNX Unified, and VNX Gateway. 2 cm); Weight Empty – 380 lbs. Unable to manage the array from the management station. 09-07-2013 07:00 AM. To install and configure Unisphere CLI, complete the following steps: Identify whether you will be using a Linux or Windows Collector to monitor your EMC VNXe device. Round-the-clock availability of spare parts through our own warehouses and logistics. March 2016 . The paper is intended to be used as a main reference for VNX Snapshot technology. /stor/prov/luns/lun show -detail. Block storage is commonly accessed using protocols such as iSCSI and Fibre Channel (FC). exe. JGroce213. When EMC launched the new VNX Series in September 2013, we anticipated adding. Click OK. The new storage solutions consolidate. Block storage offers better performance than file-level storage. I have flash 32. VNX series systems are available in the following configurations: VNX Block, VNX File, VNX Unified, and VNX Gateway. Full path to the folder containing the naviseccli. Manage your Dell EMC sites, products, and product-level contacts using Company Administration. . EMC VNX Block Block Overview provides at-a-glance heatmaps depicting the overall health of your. Avamar, VxFlex Ready Nodes, PowerFlex Appliance, PowerFlex custom node, Dell EMC Unity, VNX/VNXe, Atmos, Atmos Cloud Delivery Platform, Atmos Generation 1 Hardware, Atmos Generation 2 Hardware, Atmos Generation 3 Hardware, GeoDrive for Windows , Atmos Software Virtual Edition, Atmos Software with Atmos. . Release Notes P/N 302-000-403 REV 37 March 2020 VNX System The EMC® VNX® is a dedicated file server solution that is easily integrated into existing networks by using standard network interface protocols. Now Choose one of the initiators and click on register. 5. Request you to help me to solve the problem . The combined company will be a leader in a number of the most attractive high-growth areas of the $2 trillion information technology market. If there are, re-input the username and password in localinputs. you can convert it to a execel file and will get the detailed vnx configuraiton information. Our Operations Team where faced with an unfamiliar situation a few weeks back where we needed to re-ip an EMC VNX5300 that had it’s warranty extended and was relocated to a new Availability Zone. 021. In the right panel, the Solutions view will be displayed. There are two classes of VNX hardware producing data, VNX File and VNX Block. This add-on does not support universal forwarders because the add-on requires Python. 000. X)VNX7500 Disk Processor Enclosure helps customers to keep pace with their growing businesses by expanding their system storage capacity. This third site needs only IP connectivity to the VPLEX sites and a 3-way VPN will be established between the VPLEX management servers and the VPLEX Witness. The security features related to VNX for file are implemented on the Control Station and Data Movers. EMC recommends that you do not use user space of the vault drives for any application what will be using the disks a lot. After being introduced in 2011, the Dell EMC VNX 5100 and 5300 become End of Service Life (EoSL) on December 31, 2020. Hi Guys We haev a couple of VNX series EMC Sans at work. 4 Click the Configure icon. Hook the same switch up to to the laptop or desktop you plan to use for configuration. ClassNotFoundException: com. VNX supports SMB 3. 258 Posts. The VNX cinder driver performs the volume operations by executing Navisphere CLI (NaviSecCLI) which is a command-line interface used for management, diagnostics, and reporting functions for VNX. 33. Downloading ESRS IP Client 1. 28-12-2020 06:00 AM. This driver performs the operations on VNX by XMLAPI and the file command line. 0. PS15 – VNX SAS 15K VS07 – VNX SAS 7. The 32-bit JRE is required – even on 64 bit systems. Experience : 7+ years. The VNXe1600 is a 2U storage array supporting 10G iSCSI and 16Gb FC from EMC that integrates VNX2 controllers and hybrid storage into a package offered at street prices below $9,000. Create a large disk group and a large LUN to fill the group. 4 billion and EMC lost $119 million. Other Ethernet ports on the array, such as iSCSI or FCoE, should not be connected to the same subnets as the array management. 9. See the VMware Hardware Compatibility list for exact EMC models and. No where in. Performed the task below after the installation is complete. 5 X (Supported by collecting as a Windows Server) EMC VNX 7. Summary of Contents for EMC VNX5300. Adding VNX into Storage Domain. 33. VNX Control Station in Dell EMC VNX2 OE for File versions prior to 8. If the password is lost, you must redeploy the Solutions Integration Service and use the. Dell EMC RecoverPoint is an appliance-based product providing an alternative solution for Block Replication for Dell EMC Unity systems. workloads. Dell part A8774448. In the spcollect, you will see a file named spx_arrayconfig. VNX supports SMB 1. Supplying parts as well as carrying out Dell EMC VNX 5200 maintenance, we deliver critical support long after the manufacturer’s responsibility comes to an end. $1,623. The last digits in an EMC part number indicate storage capacity. ESRS Gateway uses ConnectEMC to send back call-home alerts. Click the “Find ESX Hosts” button. Location : Bengaluru ( work from office only ) Notice period : Need immediate joiner. This guide describes one of five models available in the VNX Series, the EMC. So, let’s startEMC Customer Education courses help you learn how EMC storage products work together within your environment to maximize your entire infrastructure investment. platform and its major components include the front and rear connectors and LED. This Management Pack provides your storage team with a robust tool for understanding and monitoring DELL EMC VNX File & Block storage systems, with the following capabilities: 10 comprehensive monitoring dashboards. For instructions on powering up a DC-powered VNX, refer to the EMC. This aids in protection against starvation. But – that enables something amazing: A VNXe 3200 with 3TB of Flash, capable of 75,000 IOps, fully unified for block and NAS use cases, and in 2U – for $25,000. VNX5300 Disk Processor Enclosure helps customers to keep pace with their growing businesses by expanding their system storage capacity. Page 31 (SPS side) on one end and a RJ-12 connector (LCC side) on the other end. In the “Find a Product” field type in “VNX/VNXe Series”, this will bring up everything relating to the VNX (both series, ie: 1 & 2)and VNXe. 1. The unit's two-rack-unit-sized enclosures fit up to 25 2. 0FC, NVMe: /FC, iSCSI, NVMe/TCP . But before we ship it back to EMC we need. Click Execute Service Action. Hi. 8 up to Update 25. Select a Model Select one Unisphere Central VNX-F Series VNX-VSS Series VNX1 Series VNX2 Series VNXe1 Series VNXe1000 Series VNXe2 Series vVNX SeriesDell EMC VNX2 OE for File was updated to address following vulnerabilities in VNX Control Station: Apache commons file upload (eliminated from VNX2 OE for File) CVE-2016-1000031. Navigate to Environment > All Objects > EMC VNX <File or Block> Adapter. Dell continues to provide updates regarding impacted and not impacted products. A Detailed Review The initial warranty on the original VNX systems expired approximately three years later, in the beginning of 2014. 33. The hard work paid off: the CX3 is now empty and we can start to decommission it. NOTE – I think this goes without saying, but if you have any doubts about. The first is the connection method we use to send commands to the cava agent. 256 VNX Operating Environment for File 8. Warning! Do NOT trespass any LUNs without first contacting TS2. rdac: Hardware handler for LSI/Engenio/NetApp RDAC class, as NetApp SANtricity E/EF Series, and OEM arrays from IBM DELL SGI STK and SUN. When adding a system into the domain, the system being added will be removed from any of its existing. Dell VNX: Unable to connect to Unisphere GUI after Java update (User Correctable) After updating Java to latest version, Unisphere may stop connecting properly. For Windows, if the VNX File metrics (sourcetype=vnx_file*) are missing for some VNX servers, check ta_vnx. Jim_Hegner. URLClassLoader. Knowledge of NetApp, HP, Hitachi Storage hands-on. Note: After the Solutions Integration Service password is changed, it cannot be modified. Field Engineer on-site (if required) within 4 hours after customer contact. Unity operates on its own while the PowerStore can operate on a cluster with up to 8 active-active nodes and the unique. Due to inadequate restrictions configured in sudores, a local authenticated malicious user may potentially execute arbitrary OS commands as root by exploiting this vulnerability. The VNX series is EMC’s next generation of midrange-to-enterprise products. Simply scroll down and select “VNX/VNXe Series” and then click the. 33. The VNX5200. Responsable de produit Stockage (Storage Product Manager-Owner) Feb 2021 - Present2 years 9 months. Check the health of the raid/disk group the lun is on, repair that first?The Dell EMC service tag is a five or more character identifier that is unique to your product. Cisco UCS Director VMware vSphere Management Guide, Release 6. Module 4: EMC VNX Administration and Interview Questions. Install the Splunk Add-on for EMC VNX Specific installation notes for this add-on. command line interface VNX EMC. Dell PowerStore is ranked 1st in All-Flash Storage with 34 reviews while Dell Unity XT is ranked 2nd in All-Flash Storage with 46 reviews. 4. We have a new VNX5300 waiting to get configured, and I need to plan out the network infrastructure before the EMC tech arrives. This particular model with part number. Storage EMC2 VNX Series Quick Start Manual. Built on proven VNX technology, the VSS100 is tuned specifically for this workload with an emphasis on. 256. The combination of high. These messages are. 5 ssd and disk drives. 47. You can view storage monitoring, graphing performance and health, alerting, and more from a. conf file, replacing “logicmonitor” with the community string that you are using. 2 Click the Administration icon. n View and Download EMC VNX Series installation and operation manual online. However, if the drive you want to hotspare doesn't show up in the list below, set the radio button to Manual. The VNX Monitoring and Reporting. The EMC VNX series unified storage systems deliver uncompromising scalability and flexibility for the mid-tier while providing market-leading simplicity and efficiency to minimize total cost of ownership. of its file systems. The VNX Family delivers industry-leading innovation and enterprise capabilities for file, block, and object storage in a scalable, easy-to-use solution. VNX arrays use the EMC SMI-S Provider open storage management interface. Increase or expand the datastore directly from the ESXi host. Given the architecture of your EMC VNX®, DefendX Software Control-Audit for NAS, EMC Edition does its job remotely. In addition to displaying this data on the Hardware Health page. This white paper provides an introduction of the VNX Storage Efficiency features on the EMC® VNXTM2 storage systems. Xeon 5600 processor with 4 GB of RAM. 3. Under System Components, select Storage System. Select an IP for your PC/laptop that is going to be in same range as your VNX will be. 1) I downloaded the MIB as per the link of emc171987 but the MIB file seems very short and like a empty template. Manage SIG's Multi Petabyte storage environment consisting of EMC XtremIO, PURE Storage, EMC VMAX, VNX's, Clariions,NetApp Cluster Mode, NetApp E-Series and. The VNX5300's intuitive design easily allows you to add new disks that can be used to expand existing storage pools or create new pools. All EMC hard drives sold by SPS Pros are previously used, fully tested, and backed by a 60 day warranty against defects. 5. 1. Data Mover failover/failure recovery mechanism is a capability of the system. 4. Check the status of the shutdown process by looking at the SP LED indicators. The series delivers file (NAS. This training covers all the key elements of VNX Block, File, and Unified deployments. By default, all VNX data is indexed into the main index. Multiple Shared File Systems service back ends need to be configured to manage multiple Data Movers. Our Operations Team where faced with an unfamiliar situation a few weeks back where we needed to re-ip an EMC VNX5300 that had it’s warranty extended and was relocated to a new Availability Zone. The naviseccli tool should be installed properly and communicating securely with the VNX infrastructure before you proceed. Comment out the following line (or similar): 6. 30-06-2016 14:00 PM. Also for: Vnx5100 dp15, Vnx5100 dp25, Vnx5300 dp15, Vnx5500 dp15, Vnx5300. Figure 17 shows an example of an SPS to LCC cable. 5". 6 TB – 15 bays ( SAS-2 ) – 6 x HD 600 GB – 8Gb Fibre Channel – Serial Attached SCSI 2 (external) – rack-mountable – 3U – field 6973. The Splunk Add-on for EMC VNX allows a Splunk® Enterprise administrator to collect inventory, performance information, and status events from VNX arrays or Control Stations. The 4U DAE will be fully installed in the EMC cabinet. Search for the initiators machine name from where you connected. Below is the deta. 86% market share. IfBased on the powerful new family of Intel Xeon- 5600 processors, the EMC VNX implements a modular architecture that integrates hardware components for block, file, and object with concurrent support for native NAS, iSCSI, Fibre Channel, and FCoE protocols. 21. 266 VNX Operating Environment for File 8. VNX5300 Disk Processor Enclosure helps customers to keep pace with their growing businesses by expanding their system storage capacity. Access 47 million research papers for free; Keep up-to-date with the latest research;Here are the steps to put them in Service mode. Quick Tip: Re-IP VNX5300. A combination of technology-focused and role-based training and exams to cover concepts and principles as well as the full range of Dell Technologies' hardware, software and solutions. Discover minute details of your enterprise storage systems automatically with LogicMonitor. 15-bay 3. 0. 6, and vmware view composer 2. Dell EMC Unity OE version 4. Steps to restart Management Services from CLI (SSH): Log in to the array over SSH (username: service) Run the command: svc_restart_service restart MGMT. Connect your PC/laptop to it too. reply from dynamox in VNX - View the full discussion. 1. Before you use the create subcommand, ensure that the /etc/netmasks file has IP-address subnet and netmask entries for all logical hostnames. While there are a variety of configurations – we are making things simple for the customers and the channel. December 2013 . I will explain where to find event logs, how to. 4. VNX family software is available in comprehensive packs or modular suites. 21. updated: 2021-10-27 18:40. EMC aims to get a jump on the virtualized storage movement with Project Liberty, a software-defined version of its VNX array that can run in hosted or cloud environments or perhaps on commodity. It reads the data from back-end storage by UltraFlex I/O technology to provide the data access. 3. mikesmith11. VNX Block Block passes through notification events only. When the user attempted to login to SPA (domain primary) the user gets an error: Unable to access security information. 4, SolarWinds introduced hardware health monitoring for selected arrays, giving you immediate insight into hardware issues in your storage environment. . EMC VNX hardware and software solutions are very simple to provision, efficient, affordable for VNX MCx™ White Paper 7 Introduction EMC’s midrange VNX systems have emerged as the de-facto standard for virtual server deployments. Cisco UCS Director Orchestration Guide, Release 6. It supports NFS, CIFS and pNFS protocols. Manoj Sivan. VNX5100™. Ms visio emc stencils download guide, emc , unity / vnx / avamar drparkatti emc. Rainer, Thank your so much for your response. VNX8000 Unified Storage Family. EMC might charge you for that also. 21. This driver performs the operations on VNX by XMLAPI and the file command line. These services consist of: Block-only—Includes a 3U disk processor enclosure (DPE), a 1U 1. 5". 7 up to Update 75. Figure 31. number label locations of orderable parts for the EMC VNX7500 platform. Now you need Unisphere Storage System Initialization Tool. Cisco UCS Director EMC VNX Management Guide, Release 5. 184 or later, these failures will normally clear a few minutes later and have no impact on data access. The. EMC Corporation (NYSE:EMC) today added new products and capabilities to the industry-leading VNX® Family of hybrid storage solutions, including a new entry-level VNXe3200 storage array.